Proximity Voltage: High - F000
Triggered and sent to the CPO in the event that the proximity signal is out of range on the high side. This occurs when the proximity signal is above 1.82VDC during active charging.
In the StatusNotification.req
use the info
field to provide the measured proximity
value at the time of failure. The units shall be VDC
.
EVSE Display Requirements
Prompt the user that an error has occured, and provide instruction to try again.
The instruction to try again should suggest confirming a properly seated connector.
If contacting Customer Service, reference error code: F000
.
Sample Message
[
2,
"12345",
"StatusNotification",
{
"connectorId": 1,
"errorCode": "OtherError",
"info": "2.00",
"status": "Finishing",
"timestamp": "2022-06-10T14:51:17Z",
"vendorId": "com.evgo.mrec",
"vendorErrorCode": "F000"
}
]