Connector Voltage: High - F008
Triggered and sent to the CPO in the event EVSE output voltage is detected above 60VDC before charging begins, or after charging ends.
In the StatusNotification.req
use the info
field to provide the measured
output voltage on the connector at the time of failure. The units shall be VDC
.
EVSE Display Requirements
Display the general Error screen, and note that the CPO has been notified.
If contacting Customer Service, reference error code: F008
.
Sample Message
[
2,
"12345",
"StatusNotification",
{
"connectorId": 1,
"errorCode": "OtherError",
"info": "70",
"status": "Faulted",
"timestamp": "2022-06-10T14:51:17Z",
"vendorId": "com.evgo.mrec",
"vendorErrorCode": "F008"
}
]