Cable Over Temperature - F009
Triggered and sent to the CPO in the event that any temperature sensor in the charging cable reads at or above the max temperature.
In the StatusNotification.req
use the info
field to provide the measured
temperature value of the thermistor at the time of failure. The units shall
be degrees C
. Omit if no measurement is available.
EVSE Display Requirements
Display the general Error screen, and note that the CPO has been notified.
If contacting Customer Service, reference error code: F009
.
Sample Message
[
2,
"12345",
"StatusNotification",
{
"connectorId": 1,
"errorCode": "OtherError",
"info": "96",
"status": "Faulted",
"timestamp": "2022-06-10T14:51:17Z",
"vendorId": "com.evgo.mrec",
"vendorErrorCode": "F009"
}
]